顯示具有 Ventilation 標籤的文章。 顯示所有文章
顯示具有 Ventilation 標籤的文章。 顯示所有文章

2012年7月19日 星期四

Attic Power Vent - Attic Ventilation Problem Solution Basics


Attic power vent warning:

Fan blades are extremely sharp! When doing any type of maintenance work around it, make sure that power supply to the motor has been turned off! Most of those vents are controlled by a heat or humidity sensing switch, and can become active/cause injury while you're performing cleaning.

Humming, muffled noise coming from above the ceiling during the summer is most likely an attic power vent, working hard to pull out hot air from under the roof (attic power vent should be placed close to the roof ridge - top, or installed as a gable vent).

The most common installations include adjustable thermostat and in some cases humidistat, which activates an attic power vent motor accordingly with your preferences (once set, it operates automatically responding to temperature or/and humidity changes).

There are also some devices preset by the manufacturer (usually between 85F - 100F), and attic power vents with no sensor at all, controlled by on/off switch mounted in various location (usually close to the attic entrance).

For the attic power vent to serve its purpose properly, and save instead of wasting your money, certain requirements have to be met:

There must be other, adequate number (or more likely square footage area) of ventilation ports installed in lower section of the roof.

Those ports are called:


soffit vents, if your house roof has an overhang, which extends beyond the house exterior wall
or gable vents - located at the attic area, commonly on the exterior wall where the two planes of a sloping roof join, forming a triangle

There's a possibility, that type of your roof allows only for installation of vents on its surface - good examples are hip roofs on many of the Chicago style Georgian type homes, which have no overhang/soffits.

In such case, if the attic power vent has been installed in upper section of the roof, passive vents should be placed not less than 1/3 of the distance between the roof bottom edge and top (ridge). Hip / ridge vent system can be also installed, or vented drip edge mounted along the roof edges.

For the attic power vent to perform efficiently, the attic floor, and all penetrations between the attic and living area of your house should be properly insulated and sealed.

Any gaps, holes, and lack or inadequate number of attic vents will cause attic power vent to create a vacuum, and remove AC cooled air from the house. In some properties, there's an open duct (or two) between the attic and utility room, which provides combustion air for gas burning appliances - it must remain open on both sides.

Make sure that the attic power vent, or its opening is protected with wire mesh / screen. Vents are usually equipped with wire mesh that wraps exterior of the fan blades housing, and prevents rodents from accessing attic area. If that screen becomes damaged and you decide to install one from the attic side, be prepared to clean it often - the birds often build nests inside the fan, especially during the cold season.

Also, some of the larger animals are strong enough to penetrate this obstacle, in the process damaging fan blades. Therefore, it's a good idea to examine your attic periodically - be careful, most attics have no flooring installed, and walking on framing is difficult / if possible, examine fan condition from attic access point.

Before installing a new attic power vent in your house attic area, make sure you properly calculate square footage area - vent calculator. If installed fan is too small, it will have to operate much longer, to move the same amount of air through the attic.

Adjusting thermostat too low might cause fan to run constantly during hot summer - try to set the temperature dial to a 100 -110 degrees Fahrenheit.

The fan should start automatically as soon as the attic temperature rises above the preset setting, and cuts off when the attic is cooled down to approximately 10% below the thermostat setting.

Go Green and try low voltage, solar battery operated power vent - saves money on installation, very quiet, but approximately 3 times as expensive, as a regular attic power vent.




For more valuable information from Dariusz Rudnicki, on how to maintain your real estate property, correct most common problems, and prevent serious disasters by doing repairs the right way, please visit http://www.checkthishouse.com

Dariusz is a licensed Illinois home inspector who has been in this business for over eleven years, crawling through the areas you'd newer expect that even exist in your house... just to let you know that everything is working properly... or not. If you have some attic ventilation, or any home maintenance related questions, you can always ask him for help.





This post was made using the Auto Blogging Software from WebMagnates.org This line will not appear when posts are made after activating the software to full version.

2012年6月25日 星期一

Energy Efficient Ventilation in Your Home


Fresh air and adequate ventilation serve more than just the physical comfort of occupants. While a healthy supply of fresh air is important proper airflow also provides condensation control, removal of airborne pollutants and ensures the safe use of potentially combustible appliances.

Insulation, heating systems and overall ventilation installations need to be considered in a group context for the most energy efficient results. Generally speaking the aim of a good ventilation installation is to maximise energy efficiency without reducing indoor air quality.

Visually the most significant disadvantage of bad ventilation is mould damage associated with high relative humidity. Kitchen and bathroom activities utilise a lot of water in particular and the supply industry has responded by producing wide ranges of domestic fans for bathroom and kitchen installations.

Environmentally-conscious home owners will be aware of the new best practise building standards available for energy efficient dwellings. Insulation or 'airtight' architecture is often used - with success - to reduce the heating energy expenditure. This 'airtightness' also contributes to more rapid build-up of internal pollutant sources such as gases, cleaning agent fumes, Allergens such as house dust mites and chemical by-products from home ware and furniture. Unless great insulation is coupled with effective ventilation negative health effects will be felt over time.

Natural airflow can easily be augmented and controlled by installation simple ventilation mechanism in the home. There is a three-point action plan to reach great home air quality goals:

One: Extractor fans installed in key areas such as kitchens, laundries and bathrooms allow for controlled air expulsion in heavy activity rooms.

Two: Whole building ventilation and air condition allows automated regulation air quality throughout the building usually via roof or floor ducting installations. Apart from timers whole building systems can also be installed to utilise sensors to determine appropriate operation times. For example an occupancy or motion sensor will allow a sensor to tailor its usage to times when the house is actually occupied and reduce the overall energy costs of ventilating.

Three: Lastly any area which is temporarily used for activities that increase pollutants (e.g.: painting or fumigating) should be physically aired by opening a window.

Ducting in existing homes will need to be installed with the minimum bends and kinks for more efficient energy flow. Another recent development to consider would be heat recovery units. These units recover heat from air being released outside to warm up incoming fresh air.

Choosing a contractor to install your energy efficient home ventilation system:

Apart from choosing an individual with a background in BER (Building Energy Rated) construction it is also a good idea to find out what their relationship with the supplier is. You want to ensure that future ventilation upgrades and repairs will not be negatively impacted by a relationship with a poor supplier. Home-owners also need to be aware that most legal requirements allow contractors to "trade off" the characteristics of units with different functions. Installing a system using only the minimum performance statistics for all units will not usually add up to a fully compliant home build.




Ventac manufactures and supplies industrial and home ventilation solutions in Ireland and abroad. http://www.ventac.com





This post was made using the Auto Blogging Software from WebMagnates.org This line will not appear when posts are made after activating the software to full version.

2012年2月28日 星期二

Bathroom Exhaust Fan - Does Your Bathroom Need Extra Ventilation?


Most modern houses are designed to include adequate ventilation. You may notice the importance of this during the winter when windows are often kept shut and the house is heated. The hot air rises and when it condenses will turn to moisture. This allows mold and bacteria to breed and can soak into the foundations of the building. The mold and mildew is a potential hazard for the inhabitants of the house and the damp is a potential hazard for the house itself. Thus it is important that ventilation allows the air to circulate and hot air to be released.

This is certainly no more true than in the bathroom and the kitchen. The bathroom is constantly being used and this generally means using hot water for a shower, bath or shave. This causes hot vapor or steam that will rise to the ceiling. When the temperature drops in the bathroom, this steam will condense and leave moisture. This is a potential health hazard and again is not good for the long term maintenance of the room itself. Thus modern bathrooms, especially those with showers come with a bathroom exhaust fan. This article will discuss ventilating the bathroom and some things to consider in the ventilation fan.

A bathroom ventilation fan removes moist air from the room before it can condense and leave moisture on the walls and ceiling. It can also remove smells from the room. The fan is normally set to activate whenever the shower is turned on or even the ambient light. It is then set by a timer to continue running for a few minutes after the shower is turned off. This can be set on installation and changed if the air is not being removed effectively. New modifications on this include using a humidity sensor that keeps the fan running until the moisture reaches a certain level. This is probably more efficient, in terms of electricity usage, than the standard timer set up.

The industry standard for a bathroom ventilation fan is that it should be able to remove eight times the volume of air in the room every hour. This means you have to work out the volume of air that is contained in your bathroom before buying a fan. This can be done by getting the dimensions of the room (width x length). Bathroom exhaust fans are rated by cubic foot per minute. Depending on the size of the bathroom, you may also have to take into account the number of fixtures, like shower, bath, tub, sink and toilet in the room.

Another consideration of ventilation, especially during the summer months or during the day, is that you can simply open a window for ventilation. This will decrease the length of time the fan has to run for or you can switch it off for the summer. It is important to get the right fan for the size of room as it can make a rather annoying noise. If the fan is too big or room too small (or both) you might find that it makes your experience in the bathroom unsatisfying.




If you want to breathe new life into your home or are simply looking for a bit of inspiration then visit http://www.finehomeideas.com - The site gives tips and advice for home renovation and interior design, including bathroom shower ideas and ideas for bathroom cabinets. Adrian Whittle gives ideas on how to make your home special.





This post was made using the Auto Blogging Software from WebMagnates.org This line will not appear when posts are made after activating the software to full version.

2012年2月12日 星期日

How to Get Correct Air Conditioning and Ventilation Measuring in Homes


Air conditioning and ventilation engineering in homes is not an easy task to do for most common people. There's a lot of things you need to take in consideration to get all pieces of the puzzle together.

The first thing you need to do is to make 100% sure that the building have the capacity to provide sufficient ventilation in order to keep their occupants healthy and homes safe.

If you want to get all the variables right you must to go through careful planning and have lots of vital things in mind, such as high energy efficiency, hygiene and indoor air quality.

In order to be able to ideally adjust the air conditioning and ventilation systems, there's a lot of testing and adjusting to get it right according to the environment.

In all cases, make sure that ventilation systems are carefully sized to meet the right effective code requirements. Also that the equipment selected bears the HVI-Certified label and that it is installed to meet manufacturers requirements, this to assure long-term homeowner satisfaction.

The parameters required to measure air conditions are the following: flow, humidity, temperature, pressure, absolute pressure, lux, sound, CO2, volt and milliampere.

These parameters are all measurable using probes supplied by vendors like Testo, a wordwide manufacturer of professional measuring instruments for air condition and environment analysis. Testo devices all offer low energy consumption, high operational safety and long-term availability.

After eight years of continuously development Testo has produced a sensor meeting very high precision, long-term stability, response time and temperature tolerance.

Before approval for use by customers, the developers of these probes let the humidity sensor go through a thorough testing phase for more than a whole year.

Apart from their most reliable reference measuring instrument: Testo 400, Testo offers another highly precision multi-function meter for indoor air quality called Testo 435. This instrument will give you very precise numbers when testing and adjusting ventilation systems in buildings and other facilities, which is so important when you aim for satisfying results.




Testo is a world wide leading manufacturer of professional measurement instruments for air coditioning. One respected reseller of instruments like anemometer datalogger and other environment measuring instruments is the Swedish company Nordtec Instrument.





This post was made using the Auto Blogging Software from WebMagnates.org This line will not appear when posts are made after activating the software to full version.

2012年1月13日 星期五

Plan Proper Ventilation When Remodeling Your Bathroom


If you're planning a bathroom remodeling project, carefully consider ventilation. Without enough ventilation, the moisture generated in the bathroom will cause mold and mildew and can damage the walls and ceiling. A window is useful for ventilation, but you probably also want an exhaust fan. Below are some considerations in selecting and installing a bathroom fan, whether you're doing it yourself or hiring someone.

Choosing the Right Fan - Fans are rated according to how many cubic feet of moisture they can remove per minute (cfm). A 60 square foot bathroom requires a fan of 60 cfm. Make sure you get a unit that's the right size for your room. Another factor in selection is noise. Quieter fans have better motors, larger housings, and larger vents, but they are also more expensive. Some fans also come with additional features such as timers or humidity sensors which turn the unit off automatically.

Vent Outside - Those looking to cut corners sometimes vent a fan to the attic. This is a recipe for damage to the rafters and insulation of your home. When the moist bathroom air hits the colder attic surfaces it will condense. You're just moving the mold issue from the bathroom to the attic, where it can rot the wood. Instead, extend the vent through the roof and install a special bathroom exhaust fan termination cap at the end.

Electricity - If you are replacing an existing fan, you may find that the only broken piece is the fan's motor. You can buy a replacement motor at a hardware store and install it yourself. Be sure to turn off the electricity at the circuit breaker before you start. If your bathroom renovation plans call for installing a fan for the first time, it's a little trickier since you need to find a power supply. The most obvious solution is to add controls to the light switch and power it from there.




Joaquin Erazo, Jr. is the senior vice president of marketing and public relations at Case Design/Remodeling, Inc. Find a local bath remodeler near you!

Learn more about bath remodeling on our website.

(c) 2010 Joaquin Erazo, Jr.